Security systems supplied, installed and supported

We sell the system, install it and help keep it working

Paxton Net2 Access Control is available from 24/7 Security as a full-lifecycle service—not a product-only sale. We can source and resell equipment, install and configure it, troubleshoot an existing system, perform maintenance, complete expansions and provide support after turnover.

  • Equipment Sales & Resale
  • Professional Installation
  • Existing-System Service
  • Maintenance & Expansion
  • Support After Turnover

New installation: Buying new equipment? Our team can verify compatibility, install it correctly and test the complete system.

Existing system: Already own the equipment? Ask us about takeover service, repairs, maintenance, upgrades and support.

Paxton product-family guide

Paxton Net2 Access Control

Net2 is Paxton's networked access-control platform for centrally managing users, doors, schedules, events and integrations from a Windows-based system.

Where Net2 fits best

Net2 is a practical choice when access control is the primary requirement, a local Windows management environment is acceptable and the project benefits from Paxton's established controller and integration ecosystem.

Networked accessControllers communicate over the client network for centralized administration and event reporting.
Flexible expansionAdditional doors can be added without replacing the entire system architecture.
Entry integrationPaxton Entry can operate with Net2 for centralized user administration and door-event visibility.
Wireless optionsCompatible PaxLock and Net2 wireless products can address selected openings where cabling is difficult.

Net2 software, controllers and readers

The Net2 server and software provide the central database for people, credentials, access levels, schedules, events and reports. Net2 controllers make door decisions and supervise opening hardware. Reader selection determines credential compatibility and may affect a future migration, so the credential technology should be documented instead of described only as “proximity.”

The physical door remains a coordinated assembly. The controller must be matched to lock current, power supply, door contact, request-to-exit method, fire-alarm release behavior and any local annunciation. Existing doors should be surveyed for frame condition, egress hardware, handing, accessibility and available pathways before a bill of materials is finalized.

  • Net2 server and client software
  • Networked door controllers and I/O modules
  • Paxton or compatible readers and credentials
  • Lock, power, sensing and egress hardware

Net2 versus Paxton10

Net2 and Paxton10 should be compared by operating needs, not by assuming one is universally newer or better. Net2 focuses on established networked access control and a Windows software environment. Paxton10 combines access and video in a browser-based platform and uses a different controller backbone. A project that requires tightly unified Paxton video may favor Paxton10, while a project centered on access control and existing Net2 infrastructure may favor Net2.

A migration decision should account for controller compatibility, reader reuse, credentials, database conversion, Entry components, wireless locks, integrations, training and downtime. A staged migration may be appropriate, but two platforms can also create extra administrative work if the division of sites and responsibilities is not clear.

  • Management and hosting preference
  • Existing Net2 investment and component condition
  • Need for unified Paxton video
  • Migration cost, disruption and training
Net2 and Paxton10 planning comparison
AreaNet2Paxton10
Primary modelNetworked access controlUnified access control and video management
Management environmentWindows-based Net2 softwareBrowser-based Paxton10 environment
Controller backboneNet2 controllersPaxton10 controllers
Best decision methodMatch existing investment and access requirementsMatch unified video, remote and multi-site requirements

Integrations, wireless doors and visitor entry

Net2 can exchange information with approved third-party integrations and can coordinate access events with Entry and other building systems. Integration requirements should be written as testable outcomes: which event moves between systems, how quickly it appears, who owns the interface and what happens during a communication failure.

Wireless locks can reduce pathway and door-modification work on appropriate interior openings, but they introduce batteries, radio coverage and different maintenance tasks. Entry adds video calling and door release; panel location, lighting, accessibility, call routing, concierge functions and after-hours handling should be designed as part of the entrance workflow.

  • Approved integration and data-flow review
  • PaxLock suitability and battery-maintenance plan
  • Entry panel, monitor and call-routing design
  • Failure-mode and operator-response testing

Lifecycle and support planning

Document the installed Net2 software version, controller models, reader technologies, license or edition information, backup location and administrator ownership. Before an upgrade, review release guidance and compatibility through Paxton’s official resources. Do not apply firmware simply because a newer file exists; confirm the reason, dependencies, rollback plan and maintenance window.

Regular service should include database backup verification, controller communication review, power and battery inspection, door-hardware testing, alarm-event review and credential cleanup. The client should know which issues belong to access-control software, the network, the door hardware or another integrated system.

  • Version and hardware inventory
  • Database backup and restore procedure
  • Planned software and firmware review
  • Door, power and communication health checks

How we plan and deliver the work

The final design depends on site conditions, existing systems, client policies and the selected manufacturer or platform.

Survey

Inventory openings, controllers, readers, credentials, software and network conditions.

Compare

Evaluate retention, expansion or migration against operational requirements.

Implement

Install and test doors, software, integrations and event workflows.

Maintain

Document backups, versions, support resources and recurring health checks.

Information to gather before design

Good decisions are easier when the project team starts with complete operational and technical information. The following items help reduce assumptions, change orders and avoidable return visits.

  • Existing Net2 software version and server details
  • Controller, reader and credential inventory
  • Door hardware and power requirements
  • Entry, PaxLock and third-party integration needs
  • Expansion, migration and service-window constraints

Frequently asked questions

These are common planning questions. A site-specific answer should be confirmed during discovery and design.

Is Net2 being replaced by Paxton10?

Paxton continues to present Net2 and Paxton10 as separate systems. Selection should be based on project requirements and the installed environment.

Can Net2 work with Paxton Entry?

Yes. Paxton Entry can be integrated with Net2, with the required Entry and Net2 components selected for the design.

Can existing readers always be reused?

Not always. Reuse depends on reader protocol, credential technology, wiring, condition and the target controller platform.

Should firmware files be downloaded from an installer website?

No. Use Paxton’s official product and support resources so that the file, documentation and compatibility guidance come from the manufacturer.

Manufacturer software, firmware and technical files remain on the manufacturer’s official website. We do not mirror firmware files locally.

Discuss a commercial security project

Tell us about the doors, buildings, users, existing equipment, operational requirements and desired completion date. We will help organize the right discovery and design conversation.

Contact 24/7 Security